Check the suction and discharge pipes for obstructions. Also check the function of the Non-Return Valve.
The Non Return Valve is a black plastic cylinder which should be connected directly to the pump's inlet (not at the end of a hose). It can be checked for blockage by pushing a finger into the inlet end, the valve plate should move with minimal resistance.